    Point Source Bailer

    Point Source Bailer Design

    Bailer Capacity (per 2 ft. Length)

    Method of Operation

    Specifications


GroundwaterSoftware.com - Solinst 429 Point Source Bailer

 

Point source sampling is ideal for obtaining high quality, representative sample profiling of groundwater from specific depths. It allows the collection of water that has just flowed into a well at the desired point of sample profiling. This can avoid purging and disposal of purged water.

The Solinst 429 Point Source Bailer can be used to profile an open borehole or screened well, collecting samples from distinct levels or points of inflow. Sample biases due to mixing of the sample with water from different levels in the well is minimized by the Solinst 429 Point Source Bailer.

For point source sampling and sample profiling, GroundwaterSoftware.com also sells the Model 425 Discrete Interval Sampler which is pressurized before lowering into the well. This prevents water from entering the sampler until the desired depth has been reached. (See Model 425 Data Sheet on GroundwaterSoftware.com)

Back to Page Content


Point Source Bailer Design

 

The Solinst Point Source Bailer has dual ball valves, top and bottom. It is a simple and cost effective device for aquifer profiling available from GroundwaterSoftware.com. It needs no costly or hard to transport ancillary equipment, making it ideal for point source sampling and sample profiling in hard to access locations.

The miniature 0.5” (12.7 mm) diameter model is ideal for use in narrow tubes and direct push devices.

Back to Page Content


Bailer Capacity (per 2 ft. Length)

 

 

Point Source Bailers come in standard lengths of 2 ft. (610 mm), 3 ft. (910 mm), or 4 ft. (1220 mm)

Back to Page Content


Method of Operation

 

The bailer is lowered slowly to the desired sample depth on a support line. As the bailer is being lowered, both ball valves open, allowing water to flow through the sampler.

On reaching the sampling depth, the bailer is raised slowly and steadily. The weight of water and upward movement of the bailer keep both ball valves closed. The top ball valve prevents the sample in the bailer from mixing with water at higher levels in the borehole. The bottom valve prevents the sample from leaking out of the bailer.

Once at the surface, the bailer is emptied by opening the top vent, and allowing the water to drain slowly through the sample release device into a sample container.

The Solinst 429 Point Source Bailer can then be decontaminated before taking the next sample.

 

Back to Page Content


Specifications

 

The Solinst 429 Point Source Bailer is constructed of 316 stainless steel with Teflon® ball valves and Viton® o-rings. The sampler comes complete with a stainless steel sample release device to minimize loss of volatiles during transfer to the sample container for optimal measurement of sample profiling.

The Solinst Model 103 Tag Line is recommended as a support cable for the Solinst 429 Point Source Bailer (Which is also sold by GroundwaterSoftware.com). The cable is marked every 1 ft. or 5 ft. (0.5 m or 1 m) and is mounted on an easy to use reel. (See Model 103 Data Sheet.)

Back to Page Content

"