    Level TROLL 400 Data Logger

    Level TROLL 400 Features

    Benefits of the Level TROLL 400 Data Logger

    Level TROLL 400 Specifications

    In-Situ Level TROLL 400,500, 700 and BaroTROLL Comparison


Level TROLL 400 Data Logger

 

Overview

 

The Level TROLL 400 measures and logs water level, water pressure, and temperature in a maintenance-free system ideal for long-term monitoring at flood-prone or high humidity sites. Durable titanium construction guarantees long-lasting performance in fresh or saline groundwater and surface-water environments. Available in non-vented (absolute) pressure ranges up to 1120 ft (341 m). Integrate with telemetry systems and HydroVu Data Services for real-time feedback on all of your water monitoring sites.

Back to Page Content


Level TROLL 400 Features

 

  • Sub-1 inch diameter for easy fit
  • Non-vented (absolute) pressure ranges up to 1120 ft (341 m)
  • Fully sealed, all titanium construction and sensors
  • Flexible communication protocols (4-20 mA, SDI-12, RS-485)
  • Direct-read or periodic data download capable
  • NIST calibration report
  • Rugged twist-lock cable sold separately

Back to Page Content


Benefits of the Level TROLL 400 Data Logger

 

  • Zero maintenance – No desiccant required.
  • Convenient real-time data – Open communication protocols integrate easily with existing telemetry systems and HydroVu Data Services, SCADA, or data logger/sampling system.
  • Protect your data and your equipment – Solid titanium construction outlasts specially coated data loggers, even in harsh environments.
  • Reliable data – Advanced accuracy and precision provide high quality results you can trust.
  • Streamline data collection and analysis – Powerful software with special logging modes automates water level corrections, post-processing, report generation and data export.
  • Reduce field time – Low-power loggers last 10+ years.

Back to Page Content


Level TROLL 400 Specifications

 

Weight 0.5 lbs
Dimensions  8.5 x .72 in
Level/Depth/Pressure Sensor Range 100 psia: 60 m (197 ft), 100 psig: 70 m (231 ft), 15 psig: 11 m (35 ft), 30 psia: 11 m (35 ft), 30 psig: 21 m (69 ft), 300 psia (200 m (658 ft), 300 psig: 210 m (692 ft), 5 psig: 3.5 m (11.5 ft), 500 psia: 341 m (1120 ft), 500 psig: 351 m (1153 ft)
Protocols 4-20 mA, Modbus/RS485, SDI-12
Memory 4.0 MB
Logging Modes  Event, Fast Linear, Linear
Battery Type 3.6 V lithium
Diameter 1.83 cm (0.72 in.) OD
Level/Depth/Pressure Sensor Accuracy @ 15° C ±0.05% Full Scale
Warranty 3 Year
Battery Life 10 years

Back to Page Content


In-Situ Level TROLL 400,500, 700 and BaroTROLL Comparison

 

General Level TROLL 400 Level TROLL 500 Level TROLL 700 Level BaroTROLL
Temperature ranges1 Operational: -20-80° C (-4-176° F) Storage: -40-80° C (-40-176° F) Calibrated: -5-50° C (23-122° F) Storage: -40-80° C (-40-176° F) Calibrated: -5-50° C (23-122° F) Operational: -20-80° C (-4-176° F) Storage: -40-80° C (-40-176° F) Calibrated: -5-50° C (23-122° F) Operational: -20-80° C (-4-176° F) Storage: -40-80° C (-40-176° F) Calibrated: -5-50° C (23-122° F) Operational: -20-80° C (-4- 176° F) Storage: -40-80° C (-40-176° F) Calibrated: -5-50° C (23-122° F)
Diameter 1.83 cm (0.72 in.) 1.83 cm (0.72 in.) 1.83 cm (0.72 in.) 1.83 cm (0.72 in.)
Length 21.6 cm (8.5 in.) 21.6 cm (8.5 in.) 21.6 cm (8.5 in.) 21.6 cm (8.5 in.)
Weight 197 g (0.43 lb) 197 g (0.43 lb) 197 g (0.43 lb) 197 g (0.43 lb)
Materials Titanium body; Delrin® nose cone Titanium body; Delrin nose cone Titanium body; Delrin nose cone Titanium body; Delrin nose cone
Output options Modbus/RS485, SDI-12, 4-20 mA Modbus/RS485, SDI-12, 4-20 mA Modbus/RS485, SDI-12, 4-20 mA Modbus/RS485, SDI-12, 4-20 mA
Battery type & life2 3.6V lithium; 10 years or 2M readings 3.6V lithium; 10 years or 2M readings 3.6V lithium; 10 years or 2M readings 3.6V lithium; 10 years or 2M readings
External power 8-36 VDC 8-36 VDC 8-36 VDC 8-36 VDC
Memory

Data records3

Data logs

2.0 MB

130,000

50 logs

2.0 MB

130,000

50 logs

4.0 MB

260,000

50 logs

1.0 MB

65,000

2 logs

Fastest logging rate 2 per second 2 per second 4 per second 1 per minute
Fastest output rate Modbus: 2 per second SDI-12 & 4-20 mA: 1 per second Modbus: 2 per second SDI-12 & 4-20 mA: 1 per second Modbus: 2 per second SDI-12 & 4-20 mA: 1 per second Modbus: 2 per second SDI-12 & 4-20 mA: 1 per second
Log types Linear, Fast Linear, and Event Linear, Fast Linear, and Event Linear, Fast Linear, Linear Average, Event, Step Linear, True Logarithmic Linear
Sensor Type/Material Piezoresistive; titanium Piezoresistive; titanium Piezoresistive; titanium Piezoresistive; titanium
Range Absolute (non-vented) 30 psia: 11 m (35 ft) 100 psia: 60 m (197 ft) 300 psia: 200 m (658 ft) 500 psia: 341 m (1120 ft) Absolute (non-vented) 30 psia: 11 m (35 ft) 100 psia: 60 m (197 ft) 300 psia: 200 m (658 ft) 500 psia: 341 m (1120 ft) Absolute (non-vented) 30 psia: 11 m (35 ft) 100 psia: 60 m (197 ft) 300 psia: 200 m (658 ft) 500 psia: 341 m (1120 ft) 1000 psia: 693 m (2273 ft) Gauged (vented) 5 psig: 3.5 m (11.5 ft) 15 psig: 11 m (35 ft) 30 psig: 21 m (69 ft) 100 psig: 70 m (231 ft) 300 psig: 210 m (692 ft) 500 psig: 351 m (1153 ft) 30 psia (usable up to 16.5 psi; 1.14 bar)
Accuracy4 ±0.05% full scale (FS) ±0.1% FS ±0.05% FS ±0.1% FS ±0.05% FS ±0.1% FS ±0.05% FS ±0.1% FS
Resolution ±0.005% FS or better ±0.005% FS or better ±0.005% FS or better ±0.005% FS or better
Units of measure Pressure: psi, kPa, bar, mbar, mmHg, inHg, cmH2O, inH2O Level: in., ft, mm, cm, m Pressure: psi, kPa, bar, mbar, mmHg, inHg, cmH2O, inH2O Level: in., ft, mm, cm, m Pressure: psi, kPa, bar, mbar, mmHg, inHg, cmH2O, inH2O Level: in., ft, mm, cm, m Pressure: psi, kPa, bar, mbar, mmHg, inHg, cmH2O, inH2O
Temperature Sensor Silicon Silicon Silicon Silicon
Accuracy ±0.1° C ±0.1° C ±0.1° C ±0.1° C
Resolution 0.01° C or better 0.01° C or better 0.01° C or better 0.01° C or better
Units of measure Celsius or Fahrenheit Celsius or Fahrenheit Celsius or Fahrenheit Celsius or Fahrenheit
Warranty 3 years 3 years 3 years 3 years
Notes 1 Temperature range for non-freezing liquids. 2 Typical battery life when used within the factory-calibrated temperature range. 3 1 data record = date/time plus 2 parameters logged (no wrapping) from device within the factory-calibrated temperature range. 4 Across factory-calibrated pressure range. 5 Across factory-calibrated pressure and temperature ranges. 6 Up to 5-year (total) extended warranties are available for all sensors—call for details. Delrin is a registered trademark of E.I. du Pont de Nemours and Company. Specifications are subject to change without notice

Back to Page Content