BaroTROLL-2.jpg

In-Situ BaroTROLL Data Logger

Ask a Question


Page Content

 

    BaroTROLL Data Logger

    BaroTROLL Data Logger Features

    Benefits of the BaroTROLL Data Logger

    BaroTROLL Specifications

    In-Situ Level TROLL 400,500, 700 and BaroTROLL Comparison


BaroTROLL Data Logger

 

Overview

 

The BaroTROLL Data Logger measures and logs barometric pressure and temperature, data needed to compensate for water level changes due to barometric fluctuations. Use this data logger with non-vented (absolute) Aqua TROLL 100/200 or Level TROLL 400/700 water level loggers, or use it with vented systems to calculate barometric efficiency. Baro Merge software handles the rest, automatically post-correcting water level measurements for you.

Back to Page Content


BaroTROLL Data Logger Features

 

  • Automatic atmospheric compensation for Level TROLL and Aqua TROLL water level loggers
  • Titanium construction
  • Sub-1 inch diameter for easy fit
  • Win-Situ 5 and Baro Merge software
  • NIST calibration report

Back to Page Content


Benefits of the BaroTROLL Data Logger

 

  • Simplify data processing – Software post-corrects multiple data logger files from a single unit. Easily graph data, generate reports and export to Excel or other applications.
  • Fits any deployment – Sub-1 inch construction fits small-diameter wells.
  • Easy setup and control – User-friendly software minimizes training and installation, and instruments easily connect to your telemetry system for real-time data and alerts.
  • Save money and time in the field – Rugged titanium construction outlasts specially coated data loggers, with batteries that last 10+ years.

Back to Page Content


BaroTROLL Specifications

 

Weight 0.30 lbs
Dimensions 8.5 x 0.72 in
Protocols 4-20 mA, Modbus/RS485, SDI-12
Memory 1.0 MB
Battery Type 3.6 V lithium
Diameter 1.83 cm (0.72 in.) OD
Level/Depth/Pressure Sensor Accuracy @ 15° C ±0.05% Full Scale
Warranty 3 Year
Battery Life 10 years

Back to Page Content


In-Situ Level TROLL 400,500, 700 and BaroTROLL Comparison

 

General Level TROLL 400 Level TROLL 500 Level TROLL 700 Level BaroTROLL
Temperature ranges1 Operational: -20-80° C (-4-176° F) Storage: -40-80° C (-40-176° F) Calibrated: -5-50° C (23-122° F) Storage: -40-80° C (-40-176° F) Calibrated: -5-50° C (23-122° F) Operational: -20-80° C (-4-176° F) Storage: -40-80° C (-40-176° F) Calibrated: -5-50° C (23-122° F) Operational: -20-80° C (-4-176° F) Storage: -40-80° C (-40-176° F) Calibrated: -5-50° C (23-122° F) Operational: -20-80° C (-4- 176° F) Storage: -40-80° C (-40-176° F) Calibrated: -5-50° C (23-122° F)
Diameter 1.83 cm (0.72 in.) 1.83 cm (0.72 in.) 1.83 cm (0.72 in.) 1.83 cm (0.72 in.)
Length 21.6 cm (8.5 in.) 21.6 cm (8.5 in.) 21.6 cm (8.5 in.) 21.6 cm (8.5 in.)
Weight 197 g (0.43 lb) 197 g (0.43 lb) 197 g (0.43 lb) 197 g (0.43 lb)
Materials Titanium body; Delrin® nose cone Titanium body; Delrin nose cone Titanium body; Delrin nose cone Titanium body; Delrin nose cone
Output options Modbus/RS485, SDI-12, 4-20 mA Modbus/RS485, SDI-12, 4-20 mA Modbus/RS485, SDI-12, 4-20 mA Modbus/RS485, SDI-12, 4-20 mA
Battery type & life2 3.6V lithium; 10 years or 2M readings 3.6V lithium; 10 years or 2M readings 3.6V lithium; 10 years or 2M readings 3.6V lithium; 10 years or 2M readings
External power 8-36 VDC 8-36 VDC 8-36 VDC 8-36 VDC
Memory

Data records3

Data logs

2.0 MB

130,000

50 logs

2.0 MB

130,000

50 logs

4.0 MB

260,000

50 logs

1.0 MB

65,000

2 logs

Fastest logging rate 2 per second 2 per second 4 per second 1 per minute
Fastest output rate Modbus: 2 per second SDI-12 & 4-20 mA: 1 per second Modbus: 2 per second SDI-12 & 4-20 mA: 1 per second Modbus: 2 per second SDI-12 & 4-20 mA: 1 per second Modbus: 2 per second SDI-12 & 4-20 mA: 1 per second
Log types Linear, Fast Linear, and Event Linear, Fast Linear, and Event Linear, Fast Linear, Linear Average, Event, Step Linear, True Logarithmic Linear
Sensor Type/Material Piezoresistive; titanium Piezoresistive; titanium Piezoresistive; titanium Piezoresistive; titanium
Range Absolute (non-vented) 30 psia: 11 m (35 ft) 100 psia: 60 m (197 ft) 300 psia: 200 m (658 ft) 500 psia: 341 m (1120 ft) Absolute (non-vented) 30 psia: 11 m (35 ft) 100 psia: 60 m (197 ft) 300 psia: 200 m (658 ft) 500 psia: 341 m (1120 ft) Absolute (non-vented) 30 psia: 11 m (35 ft) 100 psia: 60 m (197 ft) 300 psia: 200 m (658 ft) 500 psia: 341 m (1120 ft) 1000 psia: 693 m (2273 ft) Gauged (vented) 5 psig: 3.5 m (11.5 ft) 15 psig: 11 m (35 ft) 30 psig: 21 m (69 ft) 100 psig: 70 m (231 ft) 300 psig: 210 m (692 ft) 500 psig: 351 m (1153 ft) 30 psia (usable up to 16.5 psi; 1.14 bar)
Accuracy4 ±0.05% full scale (FS) ±0.1% FS ±0.05% FS ±0.1% FS ±0.05% FS ±0.1% FS ±0.05% FS ±0.1% FS
Resolution ±0.005% FS or better ±0.005% FS or better ±0.005% FS or better ±0.005% FS or better
Units of measure Pressure: psi, kPa, bar, mbar, mmHg, inHg, cmH2O, inH2O Level: in., ft, mm, cm, m Pressure: psi, kPa, bar, mbar, mmHg, inHg, cmH2O, inH2O Level: in., ft, mm, cm, m Pressure: psi, kPa, bar, mbar, mmHg, inHg, cmH2O, inH2O Level: in., ft, mm, cm, m Pressure: psi, kPa, bar, mbar, mmHg, inHg, cmH2O, inH2O
Temperature Sensor Silicon Silicon Silicon Silicon
Accuracy ±0.1° C ±0.1° C ±0.1° C ±0.1° C
Resolution 0.01° C or better 0.01° C or better 0.01° C or better 0.01° C or better
Units of measure Celsius or Fahrenheit Celsius or Fahrenheit Celsius or Fahrenheit Celsius or Fahrenheit
Warranty 3 years 3 years 3 years 3 years
Notes 1 Temperature range for non-freezing liquids. 2 Typical battery life when used within the factory-calibrated temperature range. 3 1 data record = date/time plus 2 parameters logged (no wrapping) from device within the factory-calibrated temperature range. 4 Across factory-calibrated pressure range. 5 Across factory-calibrated pressure and temperature ranges. 6 Up to 5-year (total) extended warranties are available for all sensors—call for details. Delrin is a registered trademark of E.I. du Pont de Nemours and Company. Specifications are subject to change without notice

Back to Page Content